Outside Size: (mm) | 7010x5570x3810 mm (LxWxH) | Inside Size(mm) | 6900x4000x2800 mm (LxWxH) |
Foundation and Floor | Foundation | Full metal foundation, two rows flat steel grids and three rows metal non-slip diamond plates, the grids are suppressive type of steel grating instead of traditional twisted steel for the cross bar steel grating. The biggest features for it are beautiful, durable and better force bearing. |
| Surface area of foundation | 10M² (area of grids) |
| Metal basement | 350mm height, the ventilation effect is better than traditional spray booth |
| Drive-in Ramps | 2Units, eachsize: 2000X1030mm, diamond plate construction |
Wall and door | Wallboard and Roof Panel | Adopt high quality double construction fireproof insulation EPS panel, thickness: 50mm |
| 3-Folded Entrance Door With Safety Glass Window | 1 set, size: 3200x2700 mm(B x H), size is bigger than traditional spray booth |
| -Operator' s Door With Safety Glass Window | Big opening: 800x2000mm (B x H), hand-made, tempering glass observation window |
Light System | Ceiling Lighting | 8Units, each4× 36W, Total 1152W, grade of lighting box' s dustproof and waterproof reach IP54 grade. |
| Side Lighting | 8Units, each2× 36W, Total 576W, grade of lighting box' s dustproof and waterproof reach IP54 grade. |
| Brightness | ≥ 1000 LUX |
Filtration System | Pre-filters | Grade G2 plate type fiber glass filter |
| Ceiling Filters | EU5 grade high efficient filter |
| Bottom filter & exhaust filter | Fibreglass paint-stop filter |
Ventilation System | Inlet fan (Direct drive motor) | Adopt big impeller turbo fan 7.5KW, 380V, 50HZ, CE |
| Outlet fan (Direct drive motor) | Adopt big impeller turbo fan 5.5KW, 380V, 50HZ, CE |
| Painting and baking exchange system | Solenoid valve+ pressure adjustment control cylinder driven damper exchange |
| Total fan Capacity | 25, 000m³ /h |
| Air Flow Speed in cabin | 0.23m/s in empty booth, 0.25-0.35m/s in loaded booth |
Heating System | Heating Exchanger | Adopt high efficient heat-resistant stainless steel as cycling heat exchanger |
| Heating Exchange Capacity | 160KW(180, 000Kcal/H) |
| Burner Model | Adopt Italy RIELLO diesel burner G20(180, 000kcal/H) |
| Heating time | 4-6minutes (from20 to 60º C) under baking status, max baking temperature is 80° C |
Control Board | Control system | Standard Y/Δ step-down start control system |
| Function | Painting, warm painting, baking, lighting, emergency stop switch, failure indication, over-temperature alarm indication |